Universal Interface

Universal interface

The THERESA test system has a universal interface that provides steam or saturated water with freely scalable parameters. The universal interface is used to connect additional components and is used in various research projects. It is suitable, for example, for analyzing the integration of thermal energy storage systems in thermal processes with different rated outputs or for investigating and testing specific components such as heat engines or heat pumps.

Universal Interface

The THERESA experimental plant has an universal interface which provides steam or saturated water with freely scalable parameters. The universal interface is used to connect further components and is used in various research projects. It is suitable, for example, for the analysis of the integration of thermal energy storage systems in thermal processes of different nominal capacities or for the investigation and testing of specific components, such as heat engines or heat pumps.

Available Media

wet steam / saturated steam 10...60 bar(g) 184...276 °C   50...300 kg/h
superheated steam 10...60 bar(g) 185...345 °C 50...300 kg/h
hot water 10...60 bar(g) 110...265 °C 50...300 kg/h


Further parameters on request!

Available media

Wet steam / saturated steam 10...60 bar(g) 184...276 °C   50...300 kg/h
Superheated steam 10...60 bar(g) 185...345 °C 50...300 kg/h
Hot water 10...60 bar(g) 110...265 °C 50...300 kg/h


Further parameters on request!